CMLA-C Series Industrial Linear Actuators
CMLA-C Series Industrial Linear Actuators

CMLA B Series - 1,000 lbs

CMLA-C Series Industrial Linear Actuators
CMLA-C Series Industrial Linear Actuators

VOLTAGE: 115 or 230 VAC
SCREW TYPE: Ball screw or trapezoidal screw
STANDARD STROKE: 3.9 to 23.6 in (100 to 600 mm)
TEMPERATURE RANGE: -4ºF to 150ºF (-20ºC to 65ºC)
ENVIRONMENTAL RATING: IP66S protection standard

Features and Benefits

FEATURES AND BENEFITS

Rated Load

Fully rated at 1000 lbs to handle dynamic loads both in compression and tension

Lifting Speed

Lifting speeds up to 1.2 in/sec at rated load

Standard stroke lengths

3.9 in, 5.9 in ,11.8 in, 17.7 in, and 23.6 in

Safety

Safety clutch aids in the prevention of damage due to accidental overload conditions

Options

OPTIONS

Screw Types

Both ball screw and trapezoidal screw models available

Motor Voltages

115Vac or 230Vac single phase

Electric brake

Standard on ball screw models

Feedback

Position feedback potentiometer

Limit Switch

Adjustable limit switches

Specifications

CMLA B Series 1000 lb Product Specifications

Capacitor Model Motor Max. Dynamic Load Max. Static Load Screw Gear Motor Power Amperage Lifting Speed Duty Cycle Capacitor Rating
# Type (lbs) N (lbs) N Type Ratio Volts Amps (in/s) mm/s (in/hr) m/hr mdf
SK6405-7-15 AC (1000) 4500 (1500) 6672 Trapezoid 14.2 115 7 (0.56) 14.2 (360) 9.1 50
192002120 AC (1000) 4500 (1500) 6672 Trapezoid 14.2 230 3.4 (0.56) 14.2 (360) 9.1 12.5
SK6405-7-15 AC (1000) 4500 (1500) 6672 Ball 8.1 115 7 (1.12) 28.5 (600) 15.2 50
192002120 AC (1000) 4500 (1500) 6672 Ball 8.1 230 3.4 (1.12) 28.5 (600) 15.2 12.5
SK6405-7-15 AC (250)§ 1112 (1500) 6672 Ball 2.1 115 7 (4.3) 109.2 (2300) 58.5 50
192002120 AC (250)§ 1112 (1500) 6672 Ball 2.1 230 3.4 (4.3) 109.2 (2300) 58.5 12.5
§Quad Speed - Lower ratio reduces rated load to 250 lbs. No clutch