DC Motor Pie Chart.pngUpdating older elevators to modern technology can significantly reduce energy costs. DC elevator machines that are properly maintained and in good working order can provide excellent ride quality and years of additional service. Preparation is key to ensuring an elevator modernization project is successful. Columbus McKinnon recommends that a motor analysis and repair company perform a DC motor evaluation before building owners begin a modernization project.

 

 

 


Contact Our Elevator Team To Discuss Your Project

DC Motor Evaluation Steps

As part of any modernization, the motors should be evaluated in accordance with the American National Standards Institute (A.N.S.I.) and Electrical Apparatus Service Association (E.A.S.A.) standards. These standards are outlined in “ANSI/EASA Standard AR100-2015” - "Recommended Practice for the Repair of Rotating Electrical Apparatus".

The service company should be experienced with DC Elevator Gearless Traction Machines and the use of ANSI/EASA AR100-2015 guidelines to provide the following:

  1. Identification of the motor and control system
  2. Condition assessment and inspection
    • Armature, field coil, interpole, and brake coil insulation condition
    • Commutator condition and commutation
    • Brush and brush rigging condition
    • Bearing and lubrication condition
    • Brake condition (pad, drum/disk, bushings and pins, linkage)
    • Fitment and mechanical integrity (shaft, lamination, sheave)
    • Air gap
  3. Testing
    • Low voltage electrical and insulation resistance
    • Brush rigging insulation resistance
    • Brake coil insulation
    • Armature winding 
    • Field coils
  4. Cleaning
  5. Repair as necessary
  6. Dynamic testing

Download our full summary of the ANSI/EASA AR100-2015 Recommnded Practices for the Repair of Rotating Electric Apparatus

Why Choose Magnetek for Modernization Projects?

DC Energy Savings.pngThe Magnetek-brand Quattro® DC is the optimal choice for a successful modernization project, offering:

  • Energy savings
  • Lower installation costs compared to AC Motor and drive replacements
  • Superior ride quality
  • Improved performance
  • Long usable life









Learn More About the Quattro DC and Request a quote today

Download this guide to plan for a successful Quattro DC drive installation from preparation to the benefits you'll receive after installation.

Download the guide

Since the first commercial installation of Quattro DC, Magnetek has continued to improve drive designs and refine installation requirements to improve long-term reliability of retained DC gearless machines.

Learn How

DC Motor Test Methods

  • Physical inspection
  • Insulation testing (before & after testing)
  • Diagnostic AC voltage drop test of motor fields
  • Infrared hot spot detection or thermography while in operation
  • Mechanical vibration analysis
  • Electrical signature analysis while in operation
  • Impedance balance measurements of armature resistance, inductance, and capacitance 

DC Motor Test Providers

Electrical Motor Repair Company
Trenton, NJ
www.elevatormotor.com

Vincent Electric Motor Co.
Oakland, CA
http://vincentelectric.com

McIntosh Industries LLC
Hillside, NJ
peter@macintoshindustries.com

Leppert-Nutmeg
Bloomfield, CT
www.leppert-nutmeg.com
Koffer Electrical
San Leandro, CA
www.koffler.com
Renown Electric Motors & Repair, Inc.
Concord, Ontario, Canada
www.renown-electric.com
Capital Electric Motor Service
Dallas, TX
www.capitalelectricmotor.com