Products

Specifications

Single Phase Jog Controls Specifications

Motor Size Voltage Height Width Depth Enclosure Mounting
Up to 1.5HP 110/115/120 VAC/1 PH/50/60 Hz
220/230/240 VAC/1 PH/50/60 Hz
16 Inches 14 Inches 6 Inches Wall Mount

NOTE: Dimensions are the same for Momentary or Maintained controls. Dimensions shown are for standard jog controls with a single electric motor.

Single Phase Jog System Control Methods

Method 1 - Single Phase Momentary Jog Controls Diagram

Single-Phase-Momentary-Jog-Controls.jpg

 
  • As the motor turns the actuator the feedback device output changes.
  • The controller reads the output from the feedback devices and displays the actuator position on the HMI
  • HMIs can display positions of multiple devices on one screen
 
  • Controllers can accept 4 – 20 mA, 0 – 10 VDC, and pulse type inputs.
  • Common feedback devices are linear sensors, potentiometers, and incremental encoders

Method 2 - Single Phase Maintained Jog Controls Diagram

Single-Phase-Maintained-Jog-Controls.jpg

 
  • As the motor turns the actuator the feedback device output changes.
  • The panel meter reads the output from the feedback device and displays the position of the actuator
 
  • Panel meters can accept 4 – 20 mA, 0 – 10 VDC, and pulse type inputs.
  • Panel meters come in AC or DC powered models.
  • Each feedback device requires its own panel meter